Filtered Search Results
Cytiva Disposable PD-10 Desalting Columns
Use for desalting and buffer exchange, as well as removal of low-molecular weight compounds. Cytiva Life Sciences™ Disposable PD-10 Desalting Columns provide fast, high-recovery.
Protein Family | Avidin |
---|---|
Content And Storage | Upon receipt store product 4°C. Product is shipped at ambient temperature. |
Target Molecule | Biotin |
Form | Solid |
Label or Dye | Unlabeled |
Thermo Scientific™ SnakeSkin™ Dialysis Tubing
Perform desalting and buffer exchange for 10 to 100 mL samples with this 3.5K, 7K, and 10K molecular weight cut-off (MWCO), ready-to-use form of traditional dialysis membrane tubing. Securely close dialysis tubing up to 50 mm flat diameter with the sturdy, non-floating tube SnakeSkin Dialysis Clips.
Product Line | SnakeSkin™ |
---|
Invitrogen™ Dynabeads™ MyOne™ Streptavidin T1
Dynabeads MyOne Streptavidin T1 beads are 1-μm monosized, monodispersed, superparamagnetic beads covalently coupled to streptavidin and intended for use in the isolation and handling of biotinylated nucleic acids, antibodies, and other biotinylated ligands.
Shipping Condition | Ambient Temperature |
---|---|
Content And Storage | Dynabeads MyOne Streptavidin T1 are supplied in PBS, pH 7.4, with 0.1% BSA and 0.02% NaN3 . Store at 2–8°C. |
Host Species | Recombinant |
Description | Recombinant streptavidin covalently coupled to Dynabeads |
Isolation Technology | Magnetic Beads |
Color | Brown |
Binding Property | 950–1,500 pmoles free biotin/mg beads |
Material | Magnetic Polystyrene |
Concentration | 10 mg/mL |
High-throughput Compatibility | Yes |
For Use With (Application) | Capture of Biotinylated Targets |
Size Distribution | CV <5% |
Regulatory Status | For Research Use Only |
Ligand Type | Streptavidin |
Format | Beads in suspension |
Preservative | 0.02% NaN3 |
For Use With (Equipment) | KingFisher™ Sample Purification System, DynaMag™ magnets |
Product Type | Streptavidin Magnetic Beads |
Sample Type | Any Sample Type |
Shelf Life | 48 months from date of manufacture |
Purification Target | Biotin |
Certifications/Compliance | ISO9001 and ISO13485 |
Product Line | Dynabeads™, MyOne™ |
Thermo Scientific™ Pierce™ Streptavidin
Purified recombinant streptavidin enables detection of biotinylated antibodies and other probes in a variety of standard assay methods including western blotting, ELISA, immunohistochemistry, and fluorescence imaging.
Content And Storage | Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, between the following temperatures: 2 to 8°C. |
---|---|
Conjugate | Unconjugated |
Target Molecule | Biotin |
Product Line | Pierce™ |
Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls
Use this versatile nitrocellulose membrane for excellent binding affinity for small proteins and peptides, as well as nucleic acids. Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
Format | Roll |
---|---|
Length (Metric) | 4 m |
Material | 100% Pure Nitrocellulose |
For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Thermo Scientific™ Pierce™ BCA Protein Assay Kits
The Pierce BCA Protein Assay Kit is a high-precision, detergent-compatible protein assay for determination of protein concentration. Pierce BCA reagents provide accurate determination of protein concentration with most sample types encountered in protein research.
Assay | BCA Assay |
---|---|
For Use With (Equipment) | Spectrophotometer, Microplate Reader |
Product Type | Protein Quantitation Assay |
For Use With (Application) | Solution-based Detection, Absorbance |
Product Line | Pierce™ |
Detection Method | Colorimetric |
Cytiva Amersham™ ECL Select™ Western Blotting Detection Reagent
Use as a high sensitivity reagent for chemiluminescent Western blotting detection. Cytiva Life Sciences™ Amersham™ ECL Select™ Western Blotting Detection Reagent provides highly intense signal output, for detection of medium to very low protein levels.
Thermo Scientific™ Slide-A-Lyzer™ G3 Dialysis Cassettes, 3.5K MWCO
Thermo Scientific Slide-A-Lyzer™ G3 Dialysis Cassettes facilitate the rapid and trouble-free dialysis of sample volumes from 0.5 to 125 mL. Unlike standard flat tubing, these innovative devices do not require knots or clips that can lead to leaking and sample loss.
MWCO | 3.5 kDa |
---|---|
Format | Cassette |
Membrane | Cellulose Membrane, Dialysis |
Green Features | Less waste |
Purification Target | Buffer Exchange, Protein |
Product Line | Slide-A-Lyzer™ |
Thermo Scientific™ X-Gluc
Effectively screen colonies with X-Gluc, a substrate for ß-glucuronidase (GUS) which is encoded by gusA, a widely used reporter gene.
Substrate Properties | Chemical Substrate |
---|---|
Product Type | X-Gluc |
Substrate Type | Beta-Glucuronidase (GUS) Substrate |
Detection Method | Colorimetric |
Thermo Scientific™ PVDF Transfer Membrane, 0.2μm, 26.5 cm x 3.75 m
PVDF Transfer Membrane, 0.2 μm, 26.5 cm x 3.75 m
Thermo Scientific™ NHS-Fluorescein (5/6-carboxyfluorescein succinimidyl ester), mixed isomer
Activated derivatives of green-fluorescent fluorescein dye to label antibodies, proteins and other molecules for fluorescence imaging (ex 494; em 518).
Content And Storage | Store desiccated at -20°C, protect from moisture |
---|---|
Description | Pierce NHS-Fluorescein |
Product Type | NHS-Fluorescein |
Label or Dye | FITC (Fluorescein) |
Reactive Moiety | Active Ester, Succinimidyl Ester, NHS Ester |
Solubility | DMF (Dimethylformamide) |
Emission | 518 |
Excitation | 494 |
Label Type | Classic Dyes |
Chemical Reactivity | Amine |
Product Line | Pierce™ |
Cytiva Amersham™ Hybond™ P 0.45μm PVDF Membrane
Use for chemiluminescent and fluorescent detection methods for proteins of > Mr 20 000. Cytiva Life Sciences™ Amersham™ Hybond™ P 0.45μm PVDF Membrane is a 0.45 μm pore size hydrophobic membrane, with high physical strength, highly suitable for stripping and reprobing.
Pore Size | 0.45 μm |
---|
Cytiva HisTrap™ HP Prepacked Columns
Purify histidine-tagged proteins directly from homogenized, unclarified cells. Cytiva HisTrap™ HP Prepacked Columns are prepacked with Ni Sepharose™ High Performance and designed for simple, high-resolution purification of histidine-tagged proteins by immobilized metal ion affinity chromatography (IMAC).
Flow Rate | 4 mL/min. (1 mL), 5 mL/min. (5 mL) |
---|---|
Type | Pre-packed Column |
Content And Storage | 4°C to 30°C |
Description | HisTrap HP are nickel-charged IMAC columns for high resolution his-tagged protein purification with high binding capacity for maximized recovery. |
Max. Operating Pressure | 5 bar (0.5 MPa, 70 psi) |
pH Range | 3 to 12 |
Material | Polypropylene |
Support Type | 6% Highly Cross-linked Agarose |
Thermo Scientific™ CL-XPosure™ Film
Thermo Scientific CL-XPosure Film is an economically priced clear-blue X-ray film especially for detection and documentation of ECL-based western blots and other chemiluminescent protein or nucleic acid assay methods.
Content And Storage | Store at room temperature. |
---|---|
Product Type | X-Ray Film |
Quantity | 100 Sheets |
Product Line | CL-Xposure |