missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Invitrogen™ ULTRAhyb™ Ultrasensitive Hybridization Buffer
Proprietary blend of hybridization accelerators and blocking agents that greatly enhance the levels of hybridization
Brand: Invitrogen™ AM8670
This item is not returnable.
View return policy
Description
- Signals that once took days to visualize are now apparent in hours
- It is supplied in four bottles containing 125mL each
- Increase the sensitivity of blot hybridization experiments
- Increase random-primed DNA probe sensitivity up to 100x; RNA probe sensitivity 20x
- Decrease hybridization time to 2 hours
- Using standard hybridization buffers, only 1 to 5% of target molecules on a blot hybridizes to probe, making blots a relatively insensitive method for nucleic acid analysis (Vernier et al. (1996) Anal Biochem 235: 11-19); With ULTRAhyb Ultrasensitive Hybridization Buffer, the hybridization reaction approaches completion, so that as few as 10,000 molecules can be detected
- Compatible with RNA and DNA probes labeled isotopically and nonisotopically in northerns, Southerns, and dot/slot blots
- Contains 50% formamide and is compatible with positively charged membranes
- Requires 10-100x less nonisotopic DNA probe than standard hybridization buffers, making it possible to perform many more hybridizations with a single labeling reaction
Applications:
DNA and RNA Purification and Analysis, Northern Blotting, Nucleic Acid Gel Electrophoresis and Blotting
Order Info
Shipping Condition: Room Temperature

Specifications
Store at 4°C. | |
Ultrasensitive Hybridization Buffer | |
Room Temperature |
Hybridization Buffer | |
125 mL |
Safety and Handling
Product Identifier
Signal Word
Hazard Category
Hazard Statement
Precautionary Statement
Supplemental information
- ULTRAhyb Ultrasensitive Hybridization Buffer
Signal Word
- Danger
Hazard Category
- Reproductive toxicity Category 1B
Hazard Statement
- H360-May damage fertility or the unborn child.
Precautionary Statement
- P280-Wear protective gloves/protective clothing/eye protection/face protection.
- P308+P313-IF exposed or concerned: Get medical advice/attention.
- P405-Store locked up.
Supplemental information
- MIXTURE LIST-Contains : Formamide
Product Content Correction
Your input is important to us. Please complete this form to provide feedback related to the content on this product.
Product Title
For Research Use Only. Not for use in diagnostic procedures.
Spot an opportunity for improvement?Share a Content Correction