missing translation for 'onlineSavingsMsg'
Learn More

CHEMetrics Mercury-Free COD Vials Kits

Contains premeasured reagents for accurate, economical determination of COD

41.00 EUR - 203.00 EUR

Specifications

Analytes Chemical Oxygen Demand (COD)
Description A fresh reagent ampoule blank must be prepared for each series of tests; therefore the number of samples that can be tested with each kit will vary.
For Use With (Application) Premeasured reagents for accurate, economical determination of COD, determination of the oxidizable organic matter content of wastewater
For Use With (Equipment) Digestor block as well as a photometer or spectrophotometer
Test Time 2 hr. digestion
View More Specs

Products 6
Product Code Brand Range Includes No. of Tests Price Quantity & Availability  
Product Code Brand Range Includes No. of Tests Price Quantity & Availability  
11893510
View Documents
CHEMetrics
K7351S
0 to 150 ppm (LR) 25 vials and instruction book 24
41.00 EUR
Pack of 25
Please to purchase this item. Need a web account? Register with us today!
11701034
View Documents
CHEMetrics
K7356
0 to 150 ppm 150 vials and instruction book 149 (except distilled water)
203.00 EUR
495mL
Please to purchase this item. Need a web account? Register with us today!
11803520
View Documents
CHEMetrics
K7361S
0 to 1500 ppm (HR) 25 vials and instruction book 24
41.00 EUR
0.08 L
Please to purchase this item. Need a web account? Register with us today!
11761044
View Documents
CHEMetrics
K7366
0 to 1500 ppm 150 vials and instruction book 149 (except distilled water)
203.00 EUR
7.13 L
Please to purchase this item. Need a web account? Register with us today!
11813520
View Documents
CHEMetrics
K7371S
0 to 15,000 ppm (HR+) 25 vials and instruction book 24
41.00 EUR
0.01 L
Please to purchase this item. Need a web account? Register with us today!
11791054
View Documents
CHEMetrics
K7376
0 to 15,000 ppm 98 vials and instruction book 97 (except distilled water)
136.00 EUR
Pack of 98
Please to purchase this item. Need a web account? Register with us today!
Description

Description

  • No need to modify or recalibrate existing equipment or procedures
  • Optical-quality glass for accuracy
  • Available in mercury and mercury-free versions
  • Standard 5/8 in. (16 mm) diameter for compatibility with standard COD reactors and spectrophotometers; can also be used in micro-COD reactors
  • Follow the EPA-approved method for compliance reporting and use potassium dichromate as the oxidizing agent, silver sulfate as the catalyst, and mercury chloride to remove chloride interference
  • Mercury-free version uses the same oxidizing agent and catalyst without the chloride compensator

Specifications

Specifications

Chemical Oxygen Demand (COD)
Premeasured reagents for accurate, economical determination of COD, determination of the oxidizable organic matter content of wastewater
2 hr. digestion
A fresh reagent ampoule blank must be prepared for each series of tests; therefore the number of samples that can be tested with each kit will vary.
Digestor block as well as a photometer or spectrophotometer
COD Vials Kit
Videos
Safety and Handling

Safety and Handling

missing translation for 'shelfLife' : 1 year

Product Identifier
  • COD Vials Kit 0-150 ppm (LR) Mercury-free

Signal Word
  • Danger

Hazard Category
  • Acute toxicity Category 3
  • LONG-TERM AQUATIC HAZARD Chronic 1
  • ACUTE AQUATIC Acute 1
  • Carcinogenicity Category 1A
  • Serious eye damage/eye irritation Category 1
  • Germ cell mutagenicity Category 1B
  • Reproductive toxicity Category 1B
  • Respiratory sensitiser Category 1
  • Skin corrosion/irritation Category 1 A
  • Skin sensitiser Category 1
  • Specific target organ toxicity Category 1

Hazard Statement
  • H314-Causes severe skin burns and eye damage.
  • H317-May cause an allergic skin reaction.
  • H318-Causes serious eye damage.
  • H331-Toxic if inhaled.
  • H334-May cause allergy or asthma symptoms or breathing difficulties if inhaled.
  • H340-May cause genetic defects.
  • H350-May cause cancer.
  • H360FD-May damage fertility. May damage the unborn child.
  • H372-Causes damage to organs.
  • H400-Very toxic to aquatic life.
  • H410-Very toxic to aquatic life with long lasting effects.

Precautionary Statement
  • P202-Do not handle until all safety precautions have been read and understood.
  • P260-Do not breathe dust/fume/gas/mist/vapours/spray.
  • P270-Do not eat, drink or smoke when using this product.
  • P271-Use only outdoors or in a well-ventilated area.
  • P272-Contaminated work clothing should not be allowed out of the workplace.
  • P273-Avoid release to the environment.
  • P280-Wear protective gloves/protective clothing/eye protection/face protection.
  • P284-¢In case of inadequate ventilation! wear respiratory protection.
  • P301+P330+P331-IF SWALLOWED: rinse mouth. Do NOT induce vomiting.
  • P302+P352-IF ON SKIN: Wash with plenty of water/.
  • P303+P361+P353-IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower.
  • P304+P340-IF INHALED: Remove person to fresh air and keep comfortable for breathing.
  • P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P310-Immediately call a POISON CENTER/doctor/.
  • P321-Specific treatment (see on this label).
  • P362+P364-Take off contaminated clothing and wash it before reuse.
  • P363-Wash contaminated clothing before reuse.
  • P391-Collect spillage.
  • P403+P233-Store in a well-ventilated place. Keep container tightly closed.
  • P405-Store locked up.
  • P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.

SDS
Documents

Documents

Product Certifications