missing translation for 'onlineSavingsMsg'
Learn More
Learn More
ICP, ICP-MS Multi-Element Standard (19 Elements) in 5% Nitric Acid (HNO3), Reagecon
Manufactured from ultra-pure metals or salts assayed by titration and ICP-MS prior to manufacture
Brand: Reagecon ICP19A10
This item is not returnable.
View return policy
Description
- ISO/IEC 17025 for the testing of ICP/ICP-MS Standards using ICP-MS (INAB Ref: 264T)
- ISO/IEC 17025 for calibration of laboratory balances (INAB Ref: 265C)
- ISO/IEC 17025 for temperature calibration in the range of -196 - +1200°C (INAB Ref: 265C)
- ISO/IEC 17025 for density measurement (INAB Ref: 264T) using Oscillating U-Tube and Bingham Pycnometry
- ISO/IEC 17025 for certain complexometric titrations (INAB Ref: 264T)
- GHS/OSHA compliant, REACH etc.
- This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple-leached pre-cleaned bottles.
- The titrimetry and spectroscopy are controlled and calibrated using separate Certified Reference Materials (CRM’s), so the product comes with two layers of traceability including NIST Standards, where available.
- All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.
- Multi-element standard (19 elements):
Description Concentration Aluminum (Al) 100 μg/mL (ppm) Barium (Ba) 5 μg/mL (ppm) Beryllium (Be) 1 μg/mL (ppm) Bismuth (Bi) 200 μg/mL (ppm) Boron (B) 15 μg/mL (ppm) Cadmium (Cd) 20 μg/mL (ppm) Chromium (Cr) 25 μg/mL (ppm) Cobalt (Co) 20 μg/mL (ppm) Copper (Cu) 30 μg/mL (ppm) Gallium (Ga) 150 μg/mL (ppm) Indium (In) 200 μg/mL (ppm) Iron (Fe) 15 μg/mL (ppm) Lead (Pb) 200 μg/mL (ppm) Manganese (Mn) 5 μg/mL (ppm) Nickel (Ni) 50 μg/mL (ppm) Silver (Ag) 50 μg/mL (ppm) Strontium (Sr) 1 μg/mL (ppm) Thallium (Tl) 40 μg/mL (ppm) Zinc (Zn) 20 μg/mL (ppm)
Specifications
Matrix: 5% HNO₃ | |
HDPE Triple-leached | |
Multi-element | |
Liquid |
Mixed concentrations of each element | |
100 mL | |
ICP, ICP-MS, AA, IC, XRF and other cation measurement techniques |
Safety and Handling
Product Identifier
Signal Word
Hazard Category
Hazard Statement
Precautionary Statement
Supplemental information
- MULTIELEMENT ICP STANDARD
Signal Word
- Danger
Hazard Category
- Serious eye damage/eye irritation Category 1
- Skin corrosion/irritation Category 2
Hazard Statement
- H315-Causes skin irritation.
- H318-Causes serious eye damage.
Precautionary Statement
- P280-Wear protective gloves/protective clothing/eye protection/face protection.
- P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313-IF exposed or concerned: Get medical advice/attention.
- P332+P313-If skin irritation occurs: Get medical advice/attention.
- P405-Store locked up.
- P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.
Supplemental information
- MIXTURE LIST-Contains : nitric acid