missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific Chemicals Phenol/TRIS saturated sol., for molecular biology, stabilized, DNAse, RNAse and Protease free

Phenol/TRIS , CAS # 96210-45-6, is a molecular biology solvent system that can be used for the isolation of DNA.

Brand:  Thermo Scientific Chemicals 327125000


Product Code. 10431212

  • 212.06 EUR / 500mL

Please to purchase this item. Need a web account? Register with us today!

Explore more special offers
This item is not returnable. View return policy

Description

Description

This Thermo Scientific Chemicals brand product was originally part of the Acros Organics product portfolio. Some documentation and label information may refer to the legacy brand. The original Acros Organics product / item code or SKU reference has not changed as a part of the brand transition to Thermo Scientific Chemicals.

General Description

  • Phenol/Tris is a solvent system consisting of phenol and Tris(Hydroxymethyl)aminomethane
  • Prepared as ready-to-use, no titration necessary

Applications

  • Commonly used in DNA isolation. Tris(Hydroxymethyl)aminomethane acts as a proton acceptor to raise pH
TRUSTED_SUSTAINABILITY
Specifications

Specifications

Phenol/TRIS saturated sol.
Stabilized, DNase, RNase and Protease Free
C6H6O
Phenol (108-95-2); Tris (hydroxymethyl) aminomethane (77-86-1)
15, 7354
Molecular Biology
500 mL
Yellow to Orange
108-95-2, 77-86-1, 7732-18-5
MFCD01632719
1.07
94.11
7.8 to 8.2 (25°C)
Solution
Product Suggestions

Product Suggestions

Videos
Safety and Handling

Safety and Handling

Product Identifier
  • Phenol/TRIS saturated sol.

Signal Word
  • Danger

Hazard Category
  • Acute toxicity Category 3
  • Skin corrosion/irritation Category 1 B
  • Serious eye damage/eye irritation Category 1
  • Germ cell mutagenicity Category 1
  • Specific target organ toxicity after repeated exposure Category 2

Hazard Statement
  • H341-Suspected of causing genetic defects.
  • H373-May cause damage to organs.
  • H311-Toxic in contact with skin.
  • H314-Causes severe skin burns and eye damage.
  • H331-Toxic if inhaled.
  • H301-Toxic if swallowed.

Precautionary Statement
  • P280-Wear protective gloves/protective clothing/eye protection/face protection.
  • P312-Call a POISON CENTER/doctor/if you feel unwell.
  • P302+P352-IF ON SKIN: Wash with plenty of water/.
  • P301+P330+P331-IF SWALLOWED: rinse mouth. Do NOT induce vomiting.
  • P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P310-Immediately call a POISON CENTER/doctor/.
  • P260-Do not breathe dust/fume/gas/mist/vapours/spray.
  • P304+P340-IF INHALED: Remove person to fresh air and keep comfortable for breathing.

SDS
Documents

Documents

Certificates
Special Offers

Special Offers

RUO – Research Use Only