HPLC Columns
HPLC Columns
- (9)
- (281)
- (588)
- (1)
- (169)
- (3)
- (853)
- (1)
- (61)
- (33)
- (8)
- (748)
- (170)
- (46)
- (6)
- (5)
- (1)
- (5)
- (14)
- (623)
- (11)
- (2)
- (30)
- (6)
- (17)
- (1)
- (5)
- (29)
- (8)
- (1)
- (2)
- (5)
- (14)
- (5)
- (4)
- (2)
- (10)
- (99)
- (2)
- (233)
- (1)
- (1)
- (2)
- (3)
- (193)
- (679)
- (1)
- (1)
- (146)
- (1)
- (2)
- (31)
- (8)
- (83)
- (444)
- (1)
- (106)
- (2)
- (400)
- (28)
- (934)
- (2)
- (2)
- (92)
- (2)
- (2)
- (11)
- (1)
- (20)
- (35)
- (1)
- (21)
- (14)
- (5)
- (23)
- (72)
- (96)
- (319)
- (41)
- (8)
- (8)
- (4)
- (37)
- (39)
- (17)
- (196)
- (10)
- (6)
- (1)
- (819)
- (2)
- (50)
- (2)
- (1,788)
- (10)
- (2)
- (63)
- (3)
- (23)
- (6)
- (5)
- (17)
- (1)
- (1)
- (753)
- (2)
- (2)
- (3)
- (66)
- (1)
- (420)
- (471)
- (213)
- (224)
- (107)
- (13)
- (601)
- (5)
- (68)
- (16)
- (5)
- (8)
- (6)
- (88)
- (172)
- (7)
- (4)
- (6)
- (16)
- (196)
- (1)
- (10)
- (2)
- (14)
- (104)
- (6)
- (2)
- (11)
- (2)
- (1)
- (9)
- (40)
- (1)
- (132)
- (35)
- (12)
- (187)
- (2)
- (1)
- (2)
- (13)
- (188)
- (48)
- (1)
- (11)
- (122)
- (2)
- (8)
- (2,466)
- (9)
- (21)
- (12)
- (10)
- (8)
- (2)
- (96)
- (11)
- (47)
- (13)
- (4)
- (4)
- (4)
Filtered Search Results
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns
Use as a robust, general-purpose column for QC/QA applications. They are high-quality, base-deactivated, fully endcapped, have similar C18 selectivity but slightly less retentive.
Pore Size | 130 Å |
---|---|
Carbon Load | 7% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L7 |
Thermo Scientific™ Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
Pore Size | 120 Å |
---|---|
Carbon Load | 18% |
Stationary Phase | C18 |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 300 m²/g |
USP Type | L1 |
Cytiva HiTrap™ GCSFSelect
Prepacked columns specifically designed for the purification of recombinant Granulocyte-colony stimulating factor (G-CSF). Based on a highly rigid agarose base matrix that allows for high flow rates at large production scales.
Particle Size | 75 μm |
---|---|
Ligand Type | Single-Chain Antibody Fragment Directed Against G-CSF |
Type | Column |
For Use With | Purification of Recombinant Granulocyte-Colony Stimulating Factor (G-CSF) |
pH | 2 to 12 |
Quantity | 5/Pk. |
Purification Target | Granulocyte-Colony Stimulating Factor (G-CSF) |
Thermo Scientific™ Hypersil™ BDS C18 Columns
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.
Carbon Load | 11% |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ NativePac OBE-1 SEC Column for Online Sample Preparation
Perform Native-MS analysis of biomacromolecules with the NativePac OBE-1 SEC Column designed for rapid exchange of non-volatile buffer components with a volatile buffer.
Thermo Scientific™ Syncronis™ C18 Columns
Use for hydrophobic interaction reversed-phase separations.
Pore Size | 100 Å |
---|---|
Carbon Load | 16% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 320 m²/g |
USP Type | L1 |
Thermo Scientific™ BioBasic™ PREP SEC 120 Size Exclusion Chromatography HPLC Columns
Achieve outstanding size separation of water soluble compounds with BioBasic™ PREP SEC 120 Size Exclusion Chromatography HPLC Columns.
Pore Size | 120 Å |
---|---|
Stationary Phase | Diol (OH) |
Temperature | 60°C |
Phase | Size Exclusion |
For Use With | Preparative Size Exclusion |
Endcapped | No |
Column Type | Size Exclusion |
For Use With (Application) | Preparative Chromatography |
Surface Area | 300 m²/g |
Max. Pressure | 4300 psi (295 bar) |
Particle Size | 5 μm |
Carbon Load | >8.2% |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Diameter (Metric) | 7.8 mm |
pH | 2 to 8 |
USP Type | L59 |
Cytiva RESOURCE™ and SOURCE™ 15 and 5RPC columns
Designed for rapid screening experiments, method development and small-scale protein purification using reversed phase chromatography
Particle Size | 15 μm |
---|---|
Ligand Type | Matrix surface |
Flow Rate | 10 mL/min |
Type | Reversed Phase Column |
Endcapped | No |
Packing Material | Polystyrene/Divinyl Benzene |
Diameter (Metric) | 6.4 mm |
pH | 1 to 12 |
Material | PEEK |
Particle Shape | Monosized |
Max. Pressure | 580 psi |
Cytiva HiTrap Albumin and IgG Depletion
HiTrap Albumin and IgG Depletion is a prepacked columns for the depletion of albumin and IgG from human serum and plasma. The columns are prepacked with high performance SepharoseTM based media with an affinity for human serum albumin (HSA) and IgG
Thermo Scientific™ μPAC™ Neo HPLC Columns
Learn more about your proteome samples with Thermo Scientific™ μPAC™ Neo HPLC columns.
Pore Size | 100 to 300 Å |
---|---|
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silicon Chip |
pH | 1.5 to 7 |
Max. Pressure | 6526 psi (450 bar) |
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
Pore Size | 100 Å |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
USP Type | L1 |
Hamilton™ PRP-1 Reversed Phase HPLC Columns, 10um Particle Size: Stainless Steel
Stable alternative to C8 or C18 Columns
Pore Size | 100 Å |
---|---|
Type | Column |
Stationary Phase | PRP-1 |
Temperature | 5°C to 85°C |
Phase | Reversed Phase |
Packing Material | PSDVB (Polystyrene Divinylbenzene) |
Column Type | Reversed Phase |
Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
pH | 1 to 13 |
Material | Stainless Steel |
Max. Pressure | 5000 psi (345 bar) |
USP Type | L21 |
Column Format | Analytical Column |
Macherey-Nagel™ Nucleosil™ C18 Reversed Phase HPLC Column, 7 μm, 4.6 mm x 250 mm
Column Format: Analytical Column; Carbon Load: 2%; Pore Size: 500 Å; Column Phase: Reversed Phase