Filtered Search Results
Thermo Scientific™ SnakeSkin™ Dialysis Tubing
Perform desalting and buffer exchange for 10 to 100 mL samples with this 3.5K, 7K, and 10K molecular weight cut-off (MWCO), ready-to-use form of traditional dialysis membrane tubing. Securely close dialysis tubing up to 50 mm flat diameter with the sturdy, non-floating tube SnakeSkin Dialysis Clips.
Product Line | SnakeSkin™ |
---|
Thermo Scientific™ Zeba™ Spin Desalting Columns, Plates, and Cartridges, 7K MWCO, 0.5–100 mL
Perform high-throughput protein recovery (7K MWCO) and sample desalting for mass spectrometry, HPLC, capillary electrophoresis, metabolite screening, and assay development with ready-to-use Thermo Scientific Pierce Zeba desalting chromatography columns, plates, and cartridges.
MWCO | 7.0 kDa |
---|---|
Column Type | Size-exclusion, Proprietary Resin |
Purification Target | Buffer Exchange, Protein |
Product Line | Zeba™ |
Thermo Scientific™ Slide-A-Lyzer™ G3 Dialysis Cassettes, 3.5K MWCO
Thermo Scientific Slide-A-Lyzer™ G3 Dialysis Cassettes facilitate the rapid and trouble-free dialysis of sample volumes from 0.5 to 125 mL. Unlike standard flat tubing, these innovative devices do not require knots or clips that can lead to leaking and sample loss.
MWCO | 3.5 kDa |
---|---|
Format | Cassette |
Membrane | Cellulose Membrane, Dialysis |
Green Features | Less waste |
Purification Target | Buffer Exchange, Protein |
Product Line | Slide-A-Lyzer™ |
Thermo Scientific™ Pierce™ Microdialysis Plates
Simultaneously process 1 to 96 samples with 10 to 100 μL volumes with this convenient rapid dialysis system that is automation compatible and disposable.
Content And Storage | Product shipped at ambient temperature. Upon receipt, store at room temperature. |
---|---|
Format | Microdialysis Plate |
Thermo Scientific™ Slide-A-Lyzer™ G3 Dialysis Cassettes, 10K MWCO
Thermo Scientific Slide-A-Lyzer™ G3 Dialysis Cassettes facilitate the rapid and trouble-free dialysis of sample volumes from 0.5 to 125 mL. Unlike standard flat tubing, these innovative devices do not require knots or clips that can lead to leaking and sample loss.
MWCO | 10 kDa |
---|---|
Format | Cassette |
Membrane | Cellulose Membrane, Dialysis |
Green Features | Less waste |
Purification Target | Buffer Exchange, Protein |
Product Line | Slide-A-Lyzer™ |
Thermo Scientific™ Slide-A-Lyzer™ G3 Dialysis Cassettes, 20K MWCO
Thermo Scientific Slide-A-Lyzer™ G3 Dialysis Cassettes facilitate the rapid and trouble-free dialysis of sample volumes from 0.5 to 125 mL. Unlike standard flat tubing, these innovative devices do not require knots or clips that can lead to leaking and sample loss.
MWCO | 20 kDa |
---|---|
Format | Cassette |
Membrane | Cellulose Membrane, Dialysis |
Green Features | Less waste |
Purification Target | Buffer Exchange, Protein |
Product Line | Slide-A-Lyzer™ |
Thermo Scientific™ Slide-A-Lyzer™ MINI Dialysis Devices, 3.5K MWCO
Perform sample buffer exchange with these 3500-MW cut-off (MWCO) disposable polypropylene cups with integrated, low-binding membranes.
Content And Storage | Store at room temperature |
---|---|
MWCO | 3.5 kDa |
Format | MINI Dialysis Device |
Membrane | Cellulose Membrane, Dialysis |
Purification Target | Buffer Exchange, Protein |
Product Line | Slide-A-Lyzer™ |
Thermo Scientific™ Rapid Equilibrium Dialysis (RED) Inserts and Plates
Equilibrium dialysis is a method used in plasma protein binding (PPB) studies to determine the amount of free, active drugs present in plasma. The Rapid Equilibrium Dialysis (RED) Device is widely accepted as the gold standard device for measuring interactions between drugs and PPB.
For Use With (Application) | Equilibrium Dialysis |
---|
Thermo Scientific™ Slide-A-Lyzer™ MINI Dialysis Devices, 10K MWCO
Perform sample buffer exchange with these 10,000-MW cut-off (MWCO) disposable polypropylene cups with integrated, low-binding membranes.
Content And Storage | Store at room temperature |
---|---|
MWCO | 10 kDa |
Format | MINI Dialysis Device |
Membrane | Cellulose Membrane, Dialysis |
Purification Target | Buffer Exchange, Protein |
Product Line | Slide-A-Lyzer™ |
Thermo Scientific™ Slide-A-Lyzer™ MINI Dialysis Devices, 20K MWCO
Perform sample buffer exchange with these 20,000-MW cut-off (MWCO) disposable polypropylene cups with integrated, low-binding membranes.
Content And Storage | Store at room temperature |
---|---|
MWCO | 20 kDa |
Format | MINI Dialysis Device |
Membrane | Cellulose Membrane, Dialysis |
Purification Target | Buffer Exchange, Protein |
Product Line | Slide-A-Lyzer™ |
Thermo Scientific™ Slide-A-Lyzer™ G3 Dialysis Cassettes, Irradiated 10K MWCO
Thermo Scientific Slide-A-Lyzer™ G3 Dialysis Cassettes facilitate the rapid and trouble-free dialysis of sample volumes from 0.5 to 125 mL. Unlike standard flat tubing, these innovative devices do not require knots or clips that can lead to leaking and sample loss.
MWCO | 10 kDa |
---|---|
Membrane | Cellulose Membrane, Dialysis |
Green Features | Less waste |
Purification Target | Buffer Exchange, Protein |
Product Line | Slide-A-Lyzer™ |
Thermo Scientific™ Slide-A-Lyzer™ G3 Dialysis Cassettes, 2K MWCO
Thermo Scientific Slide-A-Lyzer™ G3 Dialysis Cassettes facilitate the rapid and trouble-free dialysis of sample volumes from 0.5 to 125 mL. Unlike standard flat tubing, these innovative devices do not require knots or clips that can lead to leaking and sample loss.
MWCO | 2.0 kDa |
---|---|
Format | Cassette |
Membrane | Cellulose Membrane, Dialysis |
Green Features | Less waste |
Purification Target | Buffer Exchange, Protein |
Product Line | Slide-A-Lyzer™ |
Thermo Scientific™ Zeba™ Dye and Biotin Removal Spin Columns and Filter Plates, 0.5–10 mL
Enable fast and efficient removal of non-reacted fluorescent dyes, biotin, reducing agents, and crosslinkers from protein samples with Thermo Scientific Pierce Zeba Dye and Biotin Removal columns and filter plates.
Shipping Condition | Room Temperature |
---|---|
Column Type | Proprietary Resin |
Product Line | Zeba™ |
Thermo Scientific™ Float Buoys, for 0.1 mL Slide-A-Lyzer™ MINI Dialysis Devices
Thermo Scientific Slide-A-Lyzer MINI Dialysis Device Float buoys are low density polyethylene (LPDE) rafts designed to securely hold up to 25 Slide-A-Lyzer MINI Dialysis Devices (0.1 mL only) to permit array dialysis.
Thermo Scientific™ Pierce™ Polyacrylamide Spin Desalting Columns, 7K MWCO, 0.7 mL
Separate proteins and other macromolecules from low-molecular weight buffer salts and reagents with Thermo Scientific Pierce 7K MWCO (molecular-weight cutoff) Polyacrylamide Spin Desalting Columns, which are porous polyacrylamide-based gel-filtration columns for biological sample preparation.
MWCO | 7.0 kDa |
---|---|
Content And Storage | Upon receipt store at 4°C. |
Format | Spin Column |
Description | Pierce™ Polyacrylamide Spin Desalting Columns, 7K MWCO, 0.7 mL |
Product Type | Spin Desalting Column |
Column Type | Size-exclusion, Polyacrylamide Resin |
Purification Target | Buffer Exchange, Protein |
Sample Volume (Metric) | 30 to 120 μL |
Product Line | Pierce™ |