HPLC Columns
HPLC Columns
- (9)
- (281)
- (588)
- (1)
- (169)
- (3)
- (853)
- (1)
- (61)
- (33)
- (8)
- (748)
- (170)
- (46)
- (6)
- (5)
- (1)
- (5)
- (14)
- (623)
- (11)
- (2)
- (30)
- (6)
- (17)
- (1)
- (5)
- (29)
- (8)
- (1)
- (2)
- (5)
- (14)
- (5)
- (4)
- (2)
- (10)
- (99)
- (2)
- (233)
- (1)
- (1)
- (2)
- (3)
- (193)
- (679)
- (1)
- (1)
- (146)
- (1)
- (2)
- (31)
- (8)
- (83)
- (444)
- (1)
- (106)
- (2)
- (400)
- (28)
- (934)
- (2)
- (2)
- (92)
- (2)
- (2)
- (11)
- (1)
- (20)
- (35)
- (1)
- (21)
- (14)
- (5)
- (23)
- (72)
- (96)
- (319)
- (41)
- (8)
- (8)
- (4)
- (37)
- (39)
- (17)
- (196)
- (10)
- (6)
- (1)
- (819)
- (2)
- (50)
- (2)
- (1,788)
- (10)
- (2)
- (63)
- (3)
- (23)
- (6)
- (5)
- (17)
- (1)
- (1)
- (753)
- (2)
- (2)
- (3)
- (66)
- (1)
- (420)
- (471)
- (213)
- (224)
- (107)
- (13)
- (601)
- (5)
- (68)
- (16)
- (5)
- (8)
- (6)
- (88)
- (172)
- (7)
- (4)
- (6)
- (16)
- (196)
- (1)
- (10)
- (2)
- (14)
- (104)
- (6)
- (2)
- (11)
- (2)
- (1)
- (9)
- (40)
- (1)
- (132)
- (35)
- (12)
- (187)
- (2)
- (1)
- (2)
- (13)
- (188)
- (48)
- (1)
- (11)
- (122)
- (2)
- (8)
- (2,466)
- (9)
- (21)
- (12)
- (10)
- (8)
- (2)
- (96)
- (11)
- (47)
- (13)
- (4)
- (4)
- (4)
Filtered Search Results
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
Pore Size | 120 Å |
---|---|
Carbon Load | 18% |
Stationary Phase | C18 |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 300 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns
Use as a robust, general-purpose column for QC/QA applications. They are high-quality, base-deactivated, fully endcapped, have similar C18 selectivity but slightly less retentive.
Pore Size | 130 Å |
---|---|
Carbon Load | 7% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L7 |
Thermo Scientific™ Hypersil™ BDS C18 Columns
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.
Carbon Load | 11% |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ NativePac OBE-1 SEC Column for Online Sample Preparation
Perform Native-MS analysis of biomacromolecules with the NativePac OBE-1 SEC Column designed for rapid exchange of non-volatile buffer components with a volatile buffer.
Thermo Scientific™ Hypersil GOLD™ aQ C18 Polar Endcapped HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Retain and resolve polar analytes with highly aqueous mobile phases.
Pore Size | 175 Å |
---|---|
Carbon Load | 12% |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Polar |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 220 m²/g |
USP Type | L1 |
Thermo Scientific™ Syncronis™ C18 Columns
Use for hydrophobic interaction reversed-phase separations.
Pore Size | 100 Å |
---|---|
Carbon Load | 16% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 320 m²/g |
USP Type | L1 |
Thermo Scientific™ BioBasic™ PREP SEC 120 Size Exclusion Chromatography HPLC Columns
Achieve outstanding size separation of water soluble compounds with BioBasic™ PREP SEC 120 Size Exclusion Chromatography HPLC Columns.
Pore Size | 120 Å |
---|---|
Stationary Phase | Diol (OH) |
Temperature | 60°C |
Phase | Size Exclusion |
For Use With | Preparative Size Exclusion |
Endcapped | No |
Column Type | Size Exclusion |
For Use With (Application) | Preparative Chromatography |
Surface Area | 300 m²/g |
Max. Pressure | 4300 psi (295 bar) |
Particle Size | 5 μm |
Carbon Load | >8.2% |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Diameter (Metric) | 7.8 mm |
pH | 2 to 8 |
USP Type | L59 |
Thermo Scientific™ μPAC™ Neo HPLC Columns
Learn more about your proteome samples with Thermo Scientific™ μPAC™ Neo HPLC columns.
Pore Size | 100 to 300 Å |
---|---|
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silicon Chip |
pH | 1.5 to 7 |
Max. Pressure | 6526 psi (450 bar) |
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
Pore Size | 100 Å |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
USP Type | L1 |
Hamilton™ PRP-1 Reversed Phase HPLC Columns, 10um Particle Size: Stainless Steel
Stable alternative to C8 or C18 Columns
Pore Size | 100 Å |
---|---|
Type | Column |
Stationary Phase | PRP-1 |
Temperature | 5°C to 85°C |
Phase | Reversed Phase |
Packing Material | PSDVB (Polystyrene Divinylbenzene) |
Column Type | Reversed Phase |
Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
pH | 1 to 13 |
Material | Stainless Steel |
Max. Pressure | 5000 psi (345 bar) |
USP Type | L21 |
Column Format | Analytical Column |
Macherey-Nagel™ Nucleosil™ C18 Reversed Phase HPLC Column, 7 μm, 4.6 mm x 250 mm
Column Format: Analytical Column; Carbon Load: 2%; Pore Size: 500 Å; Column Phase: Reversed Phase
Thermo Scientific™ PepMap™ Neo Trap Cartridge
Use the Thermo Scientific™ PepMap™ Neo Trap Cartridge with PepMap™ Neo UHPLC Columns to filter impurities from your peptide mapping samples.
Thermo Scientific™ Hypersil™ ODS C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes.
Pore Size | 120 Å |
---|---|
Carbon Load | 10% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 170 m²/g |
USP Type | L1 |