Learn More
Invitrogen™ IL-6 Human ELISA Kit
Measure levels of human interleukin-6 in human serum, plasma (EDTA, heparin, sodium citrate), urine and culture supernatant samples using 96-well plates.
534.00 EUR - 1656.00 EUR
Specifications
Description | Human IL-6 ELISA Kit |
---|---|
Immunoassay Kit Format | Colorimetric ELISA (TMB substrate) with Plates |
Specificity | No significant cross-reaction with with human IL-1a, IL-1ß, IL-2, IL-3, IL-4, IL-5, IL-7, IL-8, IL-10, IL-12, TNFa, IFNg, IFNa, GM-CSF, or mouse IL-6 |
Measurement | Absorbance at 450nm minus absorbance at 550nm |
Precision | Intra-assay CV <10%; inter-assay CV <10% |
Product Code | Brand | Description | Sufficient For | Price | Quantity & Availability | ||||
---|---|---|---|---|---|---|---|---|---|
Product Code | Brand | Description | Sufficient For | Price | Quantity & Availability | ||||
10390964
|
Invitrogen™
EH2IL6 |
Human IL-6 ELISA Kit | 96 microplate wells |
676.00 EUR
1 set |
In Stock
Log in to see stock. |
||||
10107683
|
Invitrogen™
EH2IL62 |
Human IL-6 ELISA Kit | 2 x 96 microplate wells | N/A | |||||
10065933
|
Invitrogen™
EH2IL65 |
Human IL-6 ELISA Kit | 5 x 96 microplate wells | N/A | |||||
Description
Assay IL-6 (human interleukin-6) levels in human serum, plasma (EDTA, heparin, sodium citrate), urine and culture supernatant samples with our Thermo Scientific Human IL-6 ELISA Kits.
These human IL-6 ELISA kits use pre-titered, matched pairs of coating and detection antibodies to achieve sensitive and accurate measurement of interleukin-6 (IL-6) in samples at 50 to 100μL per well. Also included are calibrated recombinant protein standard, streptavidin-HRP, TMB substrate solution and stop solution. The complete kits contain precoated 96-well strip plate(s) and lot-optimized reagents. The economically-priced reagent kit provides validated reagents only, requiring users to coat their own plates. The antibody-pair kit consists of the matched IL-6 antibody pairs and IL-6 standard only. All components undergo quality control testing to minimize lot-to-lot variability.Target: Natural and recombinant human interleukin-6 (IL-6)
Format: Colorimetric ELISA (TMB substrate) in clear 96-well strip plate
Measurement: Absorbance at 450nm minus absorbance at 550nm
Assay Range: 10.2 to 400pg/mL
Sensitivity: < 1pg/mL
Precision: Intra-assay CV < 10%; inter-assay CV < 10%
Sample Types: Cell culture supernatant, urine, serum, plasma (EDTA, sodium citrate and heparin)
Total Assay Time: 3 hours
Sample Size: 50μL
Specificity: No significant cross-reaction with with human IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-7, IL-8, IL-10, IL-12, TNFα, IFNγ, IFNα, GM-CSF, or mouse IL-6
Includes:Complete Kits contain pre-coated antibody-plates, detection antibodies, buffers, diluents, standards, and substrates. The Reagent Kit (previously called a “Screening Set”) contains matched antibodies, standard and detection reagents but no coated plates. The Antibody Pair Kit (previously called a “MiniKit”) contains only matched antibodies and standard (no plates or detection reagents).
Specifications
Human IL-6 ELISA Kit | |
No significant cross-reaction with with human IL-1a, IL-1ß, IL-2, IL-3, IL-4, IL-5, IL-7, IL-8, IL-10, IL-12, TNFa, IFNg, IFNa, GM-CSF, or mouse IL-6 | |
Intra-assay CV <10%; inter-assay CV <10% |
Colorimetric ELISA (TMB substrate) with Plates | |
Absorbance at 450nm minus absorbance at 550nm | |
3 hr. |