UserName
Measure dissolved oxygen levels without the difficulties of membrane replacement by using this RDO™ dissolved oxygen probe.
Type | DO Probe |
---|---|
Dissolved Oxygen (Concentration Range) | 0.00 to 20.0 mg/L |
For Use With (Equipment) | Orion Star Meter with RDO input |
Sensor Types | RDO Optical Dissolved Oxygen Sensor |
Temperature (Metric) Operating | 0°C to 50°C |
Probe Type | RDO Optical Dissolved Oxygen |
Dissolved Oxygen (Saturation Range) | 0.0 to 200% |
Accurately and conveniently conduct dissolved oxygen measurements with this BOD probe, which features an integrated stirrer.
Use this dissolved oxygen (DO) probe, featuring automatic temperature compensation and convenient screw-on membrane caps, in the lab or in the field.
Connections | 9-pin MiniDIN |
---|---|
Max. Overpressure | 6 bar |
Response Time | 90% of final value in 10 sec. |
Oxygen Consumption | 0.008μg/h (mg/L)-1 at 20°C |
Sensor Types | Dual Thermally Separated |
Min. Sample Flow | 10 cm/sec. |
Drift | ∼0.1%/day |
Storage Requirements | -5°C to +50°C |
Temperature (Metric) Operating | 0°C to 50°C |
Make any pH meter a dissolved oxygen meter with this dissolved oxygen/BOD probe.
Dissolved Oxygen (Concentration Range) | 0 to 14 ppm |
---|---|
For Use With (Equipment) | Dissolved Oxygen/BOD Probe |
Sensor Types | Polarographic Dissolved Oxygen Sensor |
Temperature (Metric) Operating | 15°C to 35°C |
Designed for harsh environments. Mettler Toledo™ InLab OptiOx™ DO Sensor is an optical dissolved oxygen sensor with an integrated temperature probe and easy-to-replace sensor caps. The robust and manageable design uses RDO technology and is well suited for a wide range of applications.
Includes | Sensor probe, sensor cap, BOD adapter, protective guard, fixed cable |
---|---|
Connections | Mini-LTW (IP67) |
Temperature (Metric) Range | 0°C to 50°C |
Length (Metric) | 65 mm (shaft) |
Dissolved Oxygen (Concentration Range) | 0 to 50 mg/L |
Sensor Types | DO (Optical) |
Certifications/Compliance | CE, ISO 9001 certified |
Probe Type | Temperature Probe: NTC 30 kΩ |
Diameter (Metric) Body | 16 mm |
Dissolved Oxygen (Saturation Range) | 0 to 500% |
A selection of dissolved oxygen probes suitable for all applications.
Length (Metric) Cable | 1.80 m |
---|---|
Length (English) Cable | 5 ft. |
For Use With (Application) | Routine pH measurement |
Probe Type | DO Sensor |
Dissolved Oxygen and BOD Probe ideal for use in most laboratory and scientific environments.
Accessory for use with InLab 605 Dissolved Oxygen Electrode.
Fast and flow-free, the FDO™ 925 is ideal suited for field measurement.
The FDO™ 925 is especially suited for lab and process thanks to its compact size
With its easy handling and robust design, these electrode conductivity cells are proven 2 and 4 electrode technology. The four electrode measuring cell TetraCon™ 925 model is for medium and high conductivity.